Wire Gauge Ampacity Calculator

Enter your load current to get the smallest copper gauge that carries it safely β€” or look up any gauge's rating. Then check the run with the voltage drop calculator, because on low-voltage runs drop is usually the real limit.

Your load

Security cable in walls/conduit = β€œpower transmission”. The chassis column applies only to short leads in free air inside an enclosure.

Recommendation

β€”
smallest gauge for your load
Rating of recommended gaugeβ€”
Safety marginβ€”
Lookup resultβ€”
Ampacity says the wire won't overheat β€” it says nothing about the voltage arriving at the device. Check voltage drop for any run over ~50 ft.
ad slot

What do you need next?

LVToolbox Pro

Ready to price the whole install?

Use the free calculators for quick field checks. Then open LVToolbox Pro to design the install, build your price, and send a professional proposal.

Open LVToolbox Pro β†’

AMT Systems Ltd. Β· Toronto & GTA

Prefer a professional to handle it?

AMT Systems can assess, design, quote, and install low-voltage power and cabling across Toronto and the GTA.

Get a Free Quote from AMT Systems β†’

Copper wire ampacity table (AWG)

GaugePower transmissionChassis (free air)Common security use
24 AWG0.6 A3.5 AData pairs, Cat5e/6 conductors
22 AWG0.9 A7 AAlarm zones, readers
20 AWG1.5 A11 AMulti-conductor control
18 AWG2.3 A16 ACamera/lock power (18/2)
16 AWG3.7 A22 ASpeaker runs, longer power
14 AWG5.9 A32 APower supply feeds
12 AWG9.3 A41 ALong 24V trunks
10 AWG15 A55 AHeavy DC distribution

Ratings are conservative engineering values for copper conductors. PoE runs are governed differently β€” 802.3bt on Cat6a bundles is already engineered within the standard.

Frequently asked questions

How many amps can 18 AWG carry?

~2.3 A conservatively for bundled power transmission; up to ~16 A as free-air chassis wiring. Use the conservative number for cable runs.

Chassis vs power transmission ratings?

Chassis = short single wire in free air. Power transmission = bundled/jacketed over distance, which is what in-wall cable runs are.

Ampacity or voltage drop β€” which limits my run?

On 12/24V systems, voltage drop almost always binds first. Size with the voltage drop calculator, then sanity-check ampacity here.