Cable Voltage Drop Calculator

Long cable runs quietly starve cameras, maglocks and alarm devices of voltage. Enter the wire gauge, run length and device current to see what actually arrives at the device β€” and the maximum run for every common gauge.

Circuit details

18/2 is the most common security power cable; 22 AWG for data pairs.

Camera w/ IR β‰ˆ 500–1000 mA @12V Β· maglock β‰ˆ 500 mA Β· PIR β‰ˆ 20 mA.

Voltage at device

β€”
arriving at the device β†’ β€”
Voltage dropβ€”
Drop percentageβ€”
Round-trip copper lengthβ€”
Max run at this gauge & loadβ€”
Smallest gauge that passesβ€”
Calculations use round-trip (2Γ—) cable length and standard copper resistance at 20 Β°C.
ad slot

What do you need next?

LVToolbox Pro

Ready to price the whole install?

Use the free calculators for quick field checks. Then open LVToolbox Pro to design the install, build your price, and send a professional proposal.

Open LVToolbox Pro β†’

AMT Systems Ltd. Β· Toronto & GTA

Prefer a professional to handle it?

AMT Systems can assess, design, quote, and install low-voltage power and cabling across Toronto and the GTA.

Get a Free Quote from AMT Systems β†’

Max run reference β€” your load, all gauges

Maximum one-way cable run for the voltage, current and drop limit entered above:

GaugeMax run

Why IR night mode is where voltage drop bites

A camera that idles at 250 mA can pull 800–1000 mA when its IR array fires at dusk. A run that measured fine with a multimeter at noon drops below brownout threshold the moment every camera on the site switches to night mode at once. Always calculate at the device's maximum current, not its idle draw β€” and remember maglocks hold continuously, so they see the full drop 24/7.

Frequently asked questions

How much voltage drop is acceptable?

Design to 10% or less of supply voltage. Many 12V cameras brown out below ~10.8V, and IR mode is usually the first thing to fail.

Why do 24V devices run so much farther?

Half the current for the same wattage plus twice the allowable drop in volts β€” roughly 4Γ— the distance of 12V on the same gauge.

Why double the cable length?

Current flows out and back, so a 50 m run puts 100 m of copper in the circuit. All drop calculations use round-trip length.